This page provides handling methods and solutions for HiMill D1/D1s equipment when processing stops due to various issues during processing.
Attention:
- First troubleshoot the problem; if it's not a hardware issue, you can proceed with the following operations
- After power off, origin information will be retained, but tool compensation information will be reset to zero
- In most cases when processing stops, the tool is not broken, so after clicking tool change, there's no need to actually change the tool; just press the button to let the tool complete auto height measurement
| No. | Code Form | Equipment Status | Operation |
|---|---|---|---|
| 1 | Only one tool processing, no tool change code Example: M3 S13000 (Processing) M5 M30 |
Power Off | Restart equipment, after homing, re-import file and start processing. |
| Power On | After homing, re-import file and start processing. | ||
| 2 | Only one tool processing, but with tool change code T1M6 Example: M5 T1 M6 M3 S13000 (Processing) M5 M30 |
Power Off | 1. Restart equipment, after homing, click the tool change button in software, after auto height measurement, reset Z0, then start processing 2. Also can modify NC file, delete T1M6 code. Import modified file and can start processing directly. |
| Power On | After homing, re-import file and start processing. | ||
| 3 | Multiple tools processing, and first tool stops during processing Example: M5 T1 M6 M3 S13000 (Processing) T2 M6 (Processing) T3 M6 ... M5 M30 |
Power Off | Restart equipment, after homing, click the tool change button in software, after auto height measurement, reset Z0, then start processing |
| Power On | After homing, re-import file and start processing. | ||
| 4 | Multiple tools processing, and tool X stops during processing Example: M5 T1 M6 M3 S13000 (Processing) T2 M6 (Processing) TX M6 (Processing) T8 M6 (Processing) M5 M30 |
Power Off | Open NC file with computer, delete all code before TXM6 (keep TXM6 and all subsequent code) After homing, import modified code, click tool change button in software, after auto height measurement, reset Z0, then start processing |
| Power On | Open NC file with computer, delete all code before TXM6 (keep TXM6 and all subsequent code) After homing, import modified code, can start processing directly |